Application:
The probes are used to evaluate the immunity of ICs to direct injection of magnetic and electric field EFT pulses.
There are two versions available:
- P1202-4 / P1302-4 (without 50 Ohm termination)
- P1202-4 R50 / P1302-4 50R (with 50 Ohm termination)
The probes are positioned at a defined distance (3 or 10 mm) above the IC.
Property:
- standard EFT pulse shape according IEC 61000-4-4
Technical parameters:
EFT-Probes:
|
P1202-4 / 50R
|
P1302-4 / 50R
|
Puls shape:
|
5 / 50 ns
|
High voltage:
|
± 8 kV
|
Line impedance:
|
50 Ohm
|
Connection EFT generator:
|
50 Ohm Fischer plug socked (D103A023)
|
Measurement output:
|
50 Ohm, SMB
|
Shunt for current measurement:
|
0.1 Ohm
|
Termination:
|
50 Ohm - P1202-4 50R
|
50 Ohm - 1302-4 50R
|
Current / Voltage
correction factor R:
|
-26 dB Ohm
|
-60 dB Ohm
|
EFT H-field injection with probes P1202-4 / P1202-4 50R:
EFT E-field injection with probes P1302-4 / P1302-4 50R
詳細規格:
P1202-4/1302-4
|