IPG 506 Front-chopped-wave Generator
|
IPG 620 High-voltage Pulse Generator, specified in CCITT 12 TR 1, K17
|
Lightning surge 1.2/50 μs, 6 kV, 20 J
|
IPG 1050 High-voltage Pulse Generator, specified in CCITT 12 TR 1, K17
|
Lightning surge 1.2/50 μs, 10 kV, 50 J
|
PG 6-200 Surge current generator, 5 kA, 8/20μs
|
PG 6-400 Surge current generator, 10 kA, 8/20μs
|
EMC 2004 PULSE GENERATOR SYSTEM
|
Pulse currents:
|
8 / 20 μs, 25 kA, 1500 J
|
10 / 50 μs, 5 kA, 1500 J
|
10 / 350 μs, 600 A, 1500 J
|
10 / 700 μs, 300 A, 1500 J
|
10/1000 μs, 200 A, 1500 J
|
PG 10-1520 Surge current generator, 2*10 kA, 8/20μs
PG 6-500 Surge current generator, 2/4* 5 kV, or 100/500 A, 2/10 μs
|
PG 2-750 Surge current generator, according to FCC Part 68, TIA – 968
|
1.6kV, 10/160μs, 4*100A or 800V, 10/560μs, 2*100A
|
optional 1kV, 10/1000μs, 2*100A according to GR-1089-CORE
|
PG 4-641 Surge current generator, 3.6kV, 10/160μs, 480A
|
according to FCC Part 68, TIA – 968
|
High-voltage Pulse Generators designed for testing telecom equipment
|
PG 6-364 High-voltage Pulse Generator, specified in ITU-T/CCITT 12 TR 1, K17, K20
|
PG 6-432 Impulse Life Test Generator, specified in ITU-T/CCITT 12 TR
|
PG 6-500 Surge current generator, 2/4* 5 kV, or 100/500 A, 2/10 μs
|
PG 10-700 High-voltage Pulse Generator, specified in ITU-T/CCITT 12 TR 1, K17, K20
|
PG 10-1000 High-voltage Pulse Generator, specified in ITU-T/CCITT 12 TR 1, K17, K2
|
Lightning surge 1.2/50 μs, 10 kV, 50 J
|
Switching surge 10/700 μs, 10 kV, 1000 J
|
PG 12-1400 High-voltage Pulse Generator, specified in ITU-T/CCITT 12 TR 1,K17,K20
|
Lightning surge 1.2/50 μs, 12 kV, 70 J
|
Switching surge 10/700 μs, 12 kV, 1400 J
|
PG 14-1960 High-voltage Pulse Generator, specified in ITU-T/CCITT 12 TR K17, K20
|
Switching surge 10/700 μs, 14 kV, 1960 J
|
Switching surge 0.5/700 μs, 14 kV, 1960 J
|
PG 20-4000 High-voltage Pulse Generator, specified in U-T/CCITT12TR ,K17,K20
|
Switching surge 10/700 μs, 20 kV, 4000 J
|
PIG 1500 Power Induction Generator
|
PG 4/640 High-voltage Pulse Generator
|
HVTG 2/10 HIGH-VOLTAGE TEST UNIT, specified in CCITT, 12 TR 1, K17
|
designed for cw-testing of over-voltage protectors,
|
Open circuit output voltage: 2 kV-rms
|
Short circuit output current: 10 A-rms
|
Test interval: CW or 0-999 cycles
|